  • Automatic end-of-life detection and warn functions. When GFCI fails, the red LED light will auto-warn user to replace the receptacle

  • Safe-lock design, assure state of fixing while trip

  • Can sustain up to 6000 V & 10000 Amp current impulse instantaneously

  • Adaptable duplex outlet faceplate, load terminal can load common receptacle and other home appliances which also have ground fault protect functions

  • Prevents Line reversal miss-wire: GFCI cannot be reset and no power to the outlet if wired incorrectly

  • Overload and anti-jamming abilities

  • Provides permanent electro-magnetic motion

  • Green grounding screw as grounding connector for easy installation and recognition

  • Wall plate included

  • Wiring screw provides improved tension disc construction

  • Made of GE LEXAN 24IR High-impact resistant thermoplastic which is resistant to shock, heat, corruption and moisture

  • Works reliably in temperatures from -31 to 151 Fahrenheit

  • UL & cUL Listed & Exceeds UL943 (2008) & cUL943 (2008) technical requirements

  • Automatic end-of-life detection and warn functions. When GFCI fails, the red LED light will auto-warn user to replace the receptacle

  • Safe-lock design, assure state of fixing while trip

  • Can sustain up to 6000 V & 10000 Amp current impulse instantaneously

  • Adaptable duplex outlet faceplate, load terminal can load common receptacle and other home appliances which also have ground fault protect functions

  • Prevents Line reversal miss-wire: GFCI cannot be reset and no power to the outlet if wired incorrectly

  • Overload and anti-jamming abilities

  • Provides permanent electro-magnetic motion

  • Green grounding screw as grounding connector for easy installation and recognition

  • Wall plate included

  • Wiring screw provides improved tension disc construction

  • Made of GE LEXAN 24IR High-impact resistant thermoplastic which is resistant to shock, heat, corruption and moisture

  • Works reliably in temperatures from -31 to 151 Fahrenheit

  • UL & cUL Listed & Exceeds UL943 (2008) & cUL943 (2008) technical requirements

The Class A Rated White 15-Amp tamper resistant GFCI (Ground Fault Circuit Interrupter) duplex outlet provides electrical shock protection and prevents the risk of electrical fire caused by ground fault current. This GFCI has a built in end-of-life feature which automatically alerts the user that the receptacle is no longer effective and needs to be replaced. The GFCI also comes with a secondary green LED indicating that the receptacle is active. This tamper resistant receptacle has a spring loaded shutter that will close off the opening to prevent insertion of small foreign objects which helps improve child safety. This 15-Amp tamper resistant GFCI can be easily installed in a typical wall switch box for both residential and commercial applications. As of 2008, National Electrical Code (NEC) requires that all new and renovated facilities must use tamper resistant receptacles. The NEC also requires that GFCI receptacles must be installed in all wet & damp environments such as a kitchen, bathroom, laundry room, basement & break room. Wall Plate is Included. Manufacturer's Limited Lifetime Warranty.

Exceeds 2008 UL943 & cUL943 technical requirements
White 15 Amp 125V Tamper Resistant GFCI duplex receptacle with active green LED light
Wall Plate is Included.
Automatic end-of-life detection and warn functions, when GFCI fails, the red signal lamp will auto-warn to remind user to replace
Safe-lock design, assure fixed state while tripped
Provides permanent electro-magnetic motion
Prevents Line reversal miss-wire: GFCI cannot be reset and no power to the outlet if wired incorrectly
Overload and anti-jamming abilities
Adaptable duplex outlet faceplate, load terminal can load common receptacle and other home compliances which also have ground fault protect function
Wiring screw adopts improved tension disc construction, making 10#-14#AWF copper wire reliable connection
Made of GE LEXAN 24IR High-impact resistant thermoplastic which is resistant to shock, heat, corruption and moisture
Works reliably at temperatures from -31 to 151 Fahrenheit
Green grounding screw as grounding connector for easy installation and recognition
Can sustain up to 6000 V & 10000A current impulse instantaneously
Class A Rated GFCI
UL & cUL Listed
Manufacturer's Limited Lifetime Warranty.
The Class A Rated White 20-Amp GFCI (Ground Fault Circuit Interrupter) duplex outlet provides electrical shock protection and prevents the risk of electrical fire caused by ground fault current. This GFCI has a built in end-of-life feature which automatically alerts the user that the receptacle is no longer effective and needs to be replaced. The GFCI comes with a secondary green LED indicating that the receptacle is active. The 20-Amp GFCI receptacle can be easily installed in a typical wall circuit box for both residential and commercial applications. The duplex GFCI exceeds 2008 UL943 & cUL943 technical requirements. The National Electrical Code (NEC) requires that GFCI receptacles must be installed in all wet & damp environments. Wall Plate is Included.

20 Amp 125V GFCI duplex receptacle with active green LED light
UL & cUL Listed & Exceeds UL943 (2008) & cUL943 (2008) technical requirements
Backwire holes for quick installation
Professional Electrician Grade